Dry sampling dispersion system winner3005 laser particle size analyzer for pharmacyparticle size distribution test

Categories dry sampling laser particle size analyzer
Brand Name: Winner
Model Number: 3005
Certification: CE, ISO9001:2009
Place of Origin: China
MOQ: 1 set
Price: USD1.00 per set
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 300 sets per month
Delivery Time: 5-8 workdays
Packaging Details: wooden box
Measuring size range: 0.1-500 micron
Accuracy: <1%
Repeatability: <1%
Application: pharmacy powders
Light source: He-Ne Laser
test speed: <1 min
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Dry sampling dispersion system winner3005 laser particle size analyzer for pharmacyparticle size distribution test


    Dry sampling dispersion system winner3005 laser particle size analyzer for pharmacyparticle size distribution test



    Brief Introduction:


    Winner3005 is intelligent dry laser particle size analyzer, manual and full automatic operation modes. MIE scattering principle as basic, Converging light Fourier transform light path, Highly stable He-Ne laser and High sensitive ring photoelectric detector,guarantee good repeatability and accuracy.


    It use air as dispersion medium, and use turbulent dispersion principle with High precision feeding device, patent powder spray pump and oil-free silent gas source guaranteeing the samples to be fully dispersed. It’s fit for any dry powder materials, especially the powder that takes chemical reaction with water or changes its shape in liquid. Compared to the wet laser particle size analyzer, It’s with the same accuracy and repeatability.


    Main Specifications:


    Model NameWinner3005
    Size Range0.1-500μm
    StandardISO13320-1:1999 GB/T19077.1-2008,Q/0100JWN001-2013
    Channels Number40
    Accuracy<1% (Deviation of D50 on national standard sample)
    Repeatability<1% (Deviation of D50 on national standard sample )
    Light SourceHe-Ne laser (λ= 632.8nm, P>2.0MW)
    Dispersion MethodDry-turbulence dispersion mode
    Operation ModeManual/Automatic
    Optical Path Calibration SystemAutomatic
    Dispersing MediumCompressed air
    Test Speed<1min for each time
    Operation SystemWin XP/ Win 7
    Connection PortUSB

    Software function

    Analysis modeFree Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification
    Statistic Method

    Volume Distribution, Quantity Distribution


    Statistic Comparison

    Several Testing Results of samples

    Different batches of samples testing result,

    Samples before and after processing,

    Test result of samples in different time.


    User-defined Analysis

    Figure out percentage according to the particle size

    Figure out particle size according to the percentage

    Figure out percentage according to the particle size range

    Meet demands of representation of particle test in different industries.

    Test ReportWord, Excel,Photo( Bmp), Text etc
    Multi-language Support

    Chinese&English


    Intelligent Operation ModeAutomatically control Air flow speed, dispersion,test and analysis.Better Repeatability after remove human-factor
    VolumeL88cm×W40cm×H30cm
    Net Weight50Kg

    Main Features:

    1) Advanced testing light path.

    Converging light Fourier transform light patented technology, make scattering light not be restricted to lens aperture. Use main detector and large angle auxiliary detector efficiently collect all angles of scattering light in the testing range, ensure good testing accuracy and reliability in the whole range.


    2)Scientific dispersion system

    Turbulence dispersion patented technology and Normal shock shearing effect, make particles sufficient dispersion, Adopt wearable ceramics improve dispersion system’s working life.


    3)Human-based operation mode

    Manual and Full automatic, easy choose.


    4)High precision-automatic Three dimension light path alignment system

    It’s composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state.


    5)Intelligent data analysis

    Analysis software collect large quantity of particle information in high speed, and inverse particle distribution by unconstrained free fitting technology, then intelligent statistics and analysis of testing data, ensure accuracy and repeatability of the output.


    6) The results not only show particle distribution,the cumulative value curve and typical particle sizes( D10, D50, D90.), but also support user-defined analyze result, such as any features particle diameter from D0 to D100,Cumulative percent(greater than or less than a certain particle diameter).

    7) Users can design the test report output and display forms according to industry requirements.


    Application:

    Winner3005 is widely used for cement, ceramic, medicine, dope, dye, padding, chemical products, catalyst, braize, dust, additive, pesticide, explosive, graphite, photosensitive material, fuel, metal and nonmetal powder, calcium carbonate, kaolin and other powder materials.


    It has unique applicability and practicability, especially for those occurs chemical reactions, change shapes and loss in liquid, such as Chinese herbal medicine, magnetic materials and powder industry with wide distribution and large particle size.


    Patents Technology:


    • Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
    • Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
    • MIE scattering principle application patent No.- ZL 2013 2 0812021.4.
    • Dry particle size analyzer full sealed sample cuvette application is protected by patent No.- ZL.2011 2 0267646.8.
    • Powder dispersion pump design application is protected by patent No.-ZL 2007 2 0018648.7

    Cheap Dry sampling dispersion system winner3005 laser particle size analyzer for pharmacyparticle size distribution test for sale
    Send your message to this supplier
     
    From:
    Enter your email please.
    To: Jinan Winner Particle Instrument Stock Co., LTd.
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0